1.
Sensors (Basel) ; 24(7)2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38610559

RESUMO

The aim of this work was to assess the accuracy, repeatability, and reproducibility of a hand-held, structured-light 3D scanner (EINScan Pro 2X Plus with High Definition Prime Pack, SHINING 3D Tech. Co., Ltd., Hangzhou, China), to support its potential use in multi-site settings on lower limb prosthetics. Four limb models with different shapes were fabricated and scanned with a metrological 3D scanner (EINScan Laser FreeScan 5X, SHINING 3D Tech. Co., Ltd., Hangzhou, China) by a professional operator (OP0). Limb models were then mailed to three sites where two operators (OP1, OP2) scanned them using their own structured-light 3D scanner (same model). OP1 scanned limb models twice (OP1-A, OP1-B). OP0, OP1-A, and OP2 scans were compared for accuracy, OP1-A and OP1-B for repeatability, and OP1-A and OP2 for reproducibility. Among all comparisons, the mean radial error was <0.25 mm, mean angular error was <4°, and root mean square error of the radial distance was <1 mm. Moreover, limits of agreement were <3.5% for perimeters and volumes. By comparing these results with respect to clinically-relevant thresholds and to the literature available on other 3D scanners, we conclude that the EINScan Pro 2X Plus 3D Scanner with High Definition Prime Pack has good accuracy, repeatability, and reproducibility, supporting its use in multi-site settings.


Assuntos
Mãos , Extremidade Superior , Reprodutibilidade dos Testes , Bandagens , Extremidade Inferior/diagnóstico por imagem
2.
Med Eng Phys ; 124: 104106, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38418019

RESUMO

A well-fitting socket and a fine-tuned foot alignment are crucial elements in a running-specific prosthesis to allow Paralympic athletes with below-knee amputation to express their full competitive potential. For this reason, once a satisfactory socket-foot configuration is established after dynamic alignment, it is fundamental to reproduce the same conditions when constructing the definitive carbon fiber socket, and when renewing or constructing a back-up prosthesis, without dismantling the original. In addition, to cope with emerging needs of the athlete, it would be beneficial to implement fine-tuning adjustments of the alignment in a very controlled manner. At present, this requires elaborate bench procedures, which tend to be expensive, time consuming, prone to manual errors, cumbersome in use and most often require damaging or disposing of the current socket. In this study, we propose an original CAD/CAM workflow that allows replicating the desired socket-foot configuration for below-knee sprinting prostheses, as well as performing socket adaptations and introducing fine-tuning adjustments to the alignments. The workflow is exemplified with reference to two case studies involving elite Paralympic runners with transtibial and partial foot amputations, respectively.


Assuntos
Amputados , Membros Artificiais , Corrida , Humanos , Marcha , Fenômenos Biomecânicos , Desenho de Prótese
3.
Sensors (Basel) ; 23(11)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37299763

RESUMO

The design and fitting of prosthetic sockets can significantly affect the acceptance of an artificial limb by persons with lower limb amputations. Clinical fitting is typically an iterative process, which requires patients' feedback and professional assessment. When feedback is unreliable due to the patient's physical or psychological conditions, quantitative measures can support decision-making. Specifically, monitoring the skin temperature of the residual limb can provide valuable information regarding unwanted mechanical stresses and reduced vascularization, which can lead to inflammation, skin sores and ulcerations. Multiple 2D images to examine a real-life 3D limb can be cumbersome and might only offer a partial assessment of critical areas. To overcome these issues, we developed a workflow for integrating thermographic information on the 3D scan of a residual limb, with intrinsic reconstruction quality measures. Specifically, workflow allows us to calculate a 3D thermal map of the skin of the stump at rest and after walking, and summarize this information with a single 3D differential map. The workflow was tested on a person with transtibial amputation, with a reconstruction accuracy lower than 3 mm, which is adequate for socket adaptation. We expect the workflow to improve socket acceptance and patients' quality of life.


Assuntos
Membros Artificiais , Qualidade de Vida , Humanos , Fluxo de Trabalho , Desenho de Prótese , Amputação Cirúrgica , Cotos de Amputação , Tíbia/cirurgia